MODELS PAXTM (1/8 DIN PRESET TIMER) & PXCK (REAL-TIME CLOCK)

6-DIGIT0.56" RED SUNLIGHT READABLE DISPLAY
4 SEPARATE DISPLAYS (Timer, Counter, Real-Time Clock, and Date)
CYCLE COUNTING CAPABILITY
PROGRAMMABLE FUNCTION KEYS/USER INPUTS
FOUR SETPOINT ALARM OUTPUTS (W/Plug-in card)
COMMUNICATIONS AND BUS CAPABILITIES (W/Plug-incard)
BUSCAPABILITIES:DEVICENET, MODBUS and PROFIBUS-DP
PC SOFTWARE AVAILABLE FOR METER CONFIGURATION
NEMA 4X/IP65 SEALED FRONT BEZEL

The PXTM(PXTimer) and PXCK (PX Clock/Timer) offer many features and performance capabilities to suit a wide range of industrialapplications. Both can function as an Elapsed Timer, or Preset Timer, while thePXCK also offers Real-Time Clock with Date capability.

The Plug-in option cards allow the opportunity to configure the meter for the present application, while providing easy upgrades for future needs. Both units can function as an Elapsed Time Indicator. By using two separate signal inputs and 23 selectable timer ranges, the meters can be programmed to meet most any timing application.

With the addition of a Plug-in Setpoint card,they can easily become a dual or quad output preset timer. The PXCK can also operate as a Real-Time Clock (RTC), with the Real-Time Clock Card already installed. The meter is capable of displaying time in12 or 24-hour time formats. The 12-hour format can be displayed in hours and minutes, with or without an AM/PM indication or in hours, minutes, and seconds. The 24-hour format can be displayed in hours and minutes or in hours, minutes, and seconds. The PXCK is also capable of a calendar display in which the day, month and/or year can be displayed. The meter will recognize leap years, and can automatically adjust for Daylight Savings Time. The Real-Time Clock has the ability to externally synchronize with other PXCK meters to provide a uniform display network throughout the plant.
Once the meters have been initially configured, the parameter list may be locked out from further modification entirely, or the setpoint, timer start/stop values, counter start/stop values, RTC time SET, and Display Intensity can be made accessible. This lockout is possible through a security code or user input. The meters have been specifically designed for harsh industrial environments. With a NEMA 4X/IP65 sealed bezel and extensive testing to meet CE requirements, the meter provides a tough yet reliable application solution. ability to externally synchronize with other PXCK meters to provide a uniform display network throughout the plant. If the application calls for both a Preset Timer and a Real-Time Clock at the same time, the PXCK can handle this requirement as well. The meter provides up to four different displays, accessed via front panel push buttons or external inputs. The displays are Timer (TMR), which displays the current timer value;Count (CNT), which displays the current cycle counter value; Date (DAT),which displays the current programmed date; and Real-Time Clock, which displays the current time. A battery-backed Real-Time Clock plug-in card is provided with the PXCK. This card, which includes a lithium coin-cell battery, will maintain the time and date when main power is removed.The meters accept inputs from a variety of sources including switch contacts and outputs from CMOS or TTL circuits. The input can be configured to trigger on the edge or level of the incoming pulse. Internal jumpers are available to allow the selection for sinking inputs (active low) or sourcing inputs (active high.) The front panel keys and three user inputs are programmable to performvarious meter functions. One of the functions includes exchanging parameterlists, allowing for two separate listings of setpoint values, timer start/stopvalues, counter start/stop values and RTC daily on and off values.The meters can have up to four setpoint outputs, determined by the optionalplug-in cards. The setpoint plug-in cards provide dual FORM-C relays (5A),quad FORM-A relays (3A) or either quad sinking or quad sourcing opencollector logic outputs. The outputs can be assigned to the timer, counter, RTCdate, and RTCtime. The outputs can also be independently configured to suit avariety of control and alarm requirements. Plug-in cards can also provide serial communications. These include RS232,RS485, Modbus, DeviceNet, and Profibus-DP. Display values, setpoint alarm values and setpoint states can be controlled through serial communications. With the RS232 or RS485 communication card installed, it is possible toconfigure the meter using a Windows®based program. The meter configuration data can be saved to a file for later recall.

AC and DC supply versions.
Parts:
PXTM000: Timer, 85-250Vac, Red
PXTM010: Timer, 11-36Vdc/24Vac, Red

:.: Frequency Inputs :.

.:: IFMA ::

  • User Settable Full Scale Frequency from 0 Hz to 25 KHz
  • Four Output Operating Ranges
  • SIGNAL VOLTAGE OUTPUT (Selectable):
  • 0 to 5 VDC @ 10 mA max.
  • 0 to 10 VDC @ 10 mA max.
  • SIGNAL CURRENT OUTPUT (Selectable):
  • 0 to 20 mA @ 10 VDC min.
  • 4 to 20 mA@ 10 VDC min.
  • Programmable Input Circuit Accepts Outputs from a Variety of Sensors
  • 85 to 250 VAC, 48 to 62 Hz; 6.5 VA and 9 to 32 VDC; 2.5 W Versions Available
  • Low Frequency Cut-out and Overrange Indication
  • 3-way Electrical Isolation (Power/Input/Output)

:: IFMR ::

  • User Settable Trip Frequency, from 0.1 Hz to 25 kHz
  • Over-speed, Under-speed, and Zero-speed Detection
  • Relay Latching, Alarm Override, and Alarm Reset Functions
  • Hysteresis and Offset Functions Available
  • 85 to 250 VAC and 9 to 32 VDC Versions Available

Process Inputs

:: IAMA ::

  • 3-Way Isolation
  • Switch Selectable Inputs & Outputs
  • 100 Different Input and Output Combinations
  • 9 to 32 VDC Powered

:: AAMA ::

  • 3-Way Isolation of Analog Signals
  • Switch Selectable Inputs & Outputs
  • 100 Different Input and Output Combinations
  • 18 to 30 VDC Powered

:: AIMI ::

  • 0(4) to 20 mA Passive Loop Powered Isolator
  • Provides Input/Output Isolation

:: IAMA0006 ::

  • 3-way Isolation Of Analog Signals
  • Universal Conversion Module - Inputs And Outputs Selected Via Dip Switch Settings
  • Over 35 Input And Output Analog Conversion Combinations
  • Ultra Slim Design – Only 0.244" Wide
  • 19 To 30 VDC Power

Temperature Inputs

:: IRMA ::

  • RTD Input Module
  • User Programmable Input
  • Sensor Break Detection
  • Multiple Analog Outputs (DC Version Only)
  • Electrical Isolation
  • 9 to 32 VDC or Loop Powered Versions m

:: ITMA ::

  • Thermocouple Input Module
  • User Programmable Input
  • Sensor Break Detection
  • Multiple Analog Outputs (DC Version Only)
  • Electrical Isolation
  • 9 to 32 VDC or Loop Powered Versions