Industrial Categories
see the categories and sub-categories
- Automation Network
- Calibration Services
- Health & Safety
- Logistics
- Machinery Safety
- Monitors
- Measurement & Control
- Panel Meters
- Sensors
- - Accessories
- - Capacitive
- - Compressed Air Dew Point
- - Compressed Air-Flow
- - Compressed air oil content
- - Conductivity
- - Dissolved Oxygen
- - Distance
- - Flame-Fire
- - Flow-Air
- - Flow-Liquids
- - Flow - Solids
- - Gases-Flammable
- - Gases-Toxic
- - Humidity for High Temperature
- - Humidity - Relative
- - Inductive
- - Laser
- - Level - Continuous
- - Level - Point
- - Magnetic
- - PH
- - Photocells
- - Pressure
- - Solar
- - Temperature-Contact
- - Temperature Non-Contact
- - Ultrasonic
- Thermal Imaging
- Wireless Communication
What is the quality of your compressed air? Is Dry, Dry Enough?
Prevent damage with Compressed Air Dew Point control
The modern production technology needs compressed air. The diversity of application starts with non-processed blast air to absolute dry, oil free and sterile compressed air. Irrespective of how it is used, compressed air has to be dry. Depending on the application considerable economical damage can be caused by uncontrolled humidity irruption into the compressed air system.
Reasons that can lead to an increased pressure dew point value within the compressed air system
- Condensate at the refrigeration dryer (condensate eliminator faulty or dirty)
- Condensate overload of the refrigeration dryer
- Adsorption agent is not regenerated sufficiently
- Compressed air bypass in the bypass (valve faulty or not closed)
- Compressed air bypass in the refrigeration dryer (worn out, corroded etc.)
Water in compressed air leads to damages
- Corrosion within the pneumatic plant - Rust will develop in the ducts and functioning elements and will lead to leakages.
- Breakage of the lubricating film – Broken lubricating films lead to mechanical faults.
- Building of electric elements.
- Formation of ice in the compressed air system - At low temperatures the water within the compressed air system could freeze and cause frost damage, reduction of the diameter and blockades.
- • Material handling - High humidity leads to conglutination of materials to be transported, e. g. sugar, concrete, granulate, etc.
- Pharmaceutical - High humidity impairs powders, tablets, etc.
- Hospital - DIN 13260, EN 737-3, danger of bacteria development
The high quality standards in industry require the continuous monitoring of humidity with results which are reliable and invariable over a long period.
We provide stand-alone units or sensors with analogue output that can be integrated in to a centrally controlled system.
Sigma 211 series Dew point sensors with display
Sigma 211 Dew Point Meter / Sensor provides reliable and long term stable dew point monitoring in industrial applications, with a range of -60 … +20 °C Td. It makes it an ideal choice for dew point measurements in desiccant dryers.
The new generation of the dew point sensors offering compressed air users a plug & play solution to monitor their compressed air quality according to the ISO 8573-1.All transmitter models are available with 2-wire or 3-wire analog 4... 20 mA output signals, in addition to that the models are available with a Modbus/RTU digital interface. By offering different output signals users can profit from great flexibility and seamless integration into their process.
Additionally the dew point sensors are offered with an integrated pressure sensor, combining a pressure and dew point sensor into a single instrument. The optional OLED display directly mounted on the sensor provides on-site real time values. The display can be easily rotated by 340 ° to fit in any application.
The main body is made from high class aluminum alloy with a soft finish. The process connection is a 1.4301 (SUS 304) stainless steel connection, made to last forever. Top cover made from aluminum at the same quality as the main body. The optional display cover is made from robust Polycarbonate with ABS reinforcement to withstand the rough environment.The new generation are the successors of the previous dew point sensor, which have satisfied users for many years.
The new sensors have been redesigned from ground up, integrating the latest technology and all our experience, still they are fully backwards compatible to existing installations.
Features
✓ For Desiccant Dryers with a measurement range of -60 … +20 °C Td.
✓ Compact size makes them ideal for dryer installations.
✓ Optional display for on-site values.
✓ Display can be rotated by 340 ° to fit your needs.
✓ User friendly signal outputs: 2-wire analog 4... 20 mA or 3-wire analog 4...20 mA + Modbus/RTU.
✓ IP65 casing provides robust protection.
✓ Low maintenance costs due to stable and reliable measurements which increase calibration intervals.
✓ Measured values available in several units: °C Td • g/m3 • mg/m3 • ppmv • g/kg (@ reference pressure) • % RH.
Sigma 212 Dew point sensor
Ideal and reliable sensor for membrane or adsorption dryers.
The H212 dew point sensors provide reliable and long term stable dew point monitoring in industrial applications. The newly developed sensor features improved signal and stability in demanding industrial applications. It makes it an ideal choice for dew point measurements in desiccant dryers.
Drifts caused by temperature changes, dust and aging are eliminated by the electronics providing reliable measurements. Recalibration interval could thus be increased to 2 years.
The measured dew point is output via a 4-20 mA signal output. The compact size of the sensors make them an ideal choice for installations in tight environments. Sensor parameters such as analogue output scaling, alarm values, units etc. can easily be changed using the service kit. This kit is used to connect the sensor to a PC for configuration changes.
Features
• Dew point sensor for low dew point applications down to -50 ºC
• Long term stability
• IP65 casing provides robust protection in rough industrial environment
• Very fast response time ensures safe and reliable indication whenever dew points are out of valid ranges
• Can be installed directly into dryers through G 1/2” thread
• High accuracy of ±2 ºC dew point
Technical information
Measuring range: | Dew point: -50°Ctd...+20°Ctd Relative humidity: 0...99.9% Temperature: -30°C...+70°C |
Power supply: | 12...30 VDC |
Response time t90: |
0...-40 °C : 2 minutes -40...0 °C : 20 seconds |
Accuracy: | +/- 2 °C dew point @ -50 °C |
Pressure range: | -0.1...5.0 MPa |
Ambient condition: | 0...50 °C |
Output signal: | 4...20 mA, 3-wire |
Connection: | M12, 5 pole |
Casing: | Zinc alloy |
Classification: | IP65 |
Process connection: | G 1/2" thread (ISO 228/1) UNF 5/8" thread (on request) |
Sigma 215 Dew point sensor
Ideal and reliable sensor for refrigerant dryers.
-20 - +50°C, measuring chamber, with M12 connector (straight type)
The H215 Dew point sensor provides reliable and long term stable dew point monitoring in industrial applications. With these new models dew point measurement in refrigerant dryers becomes affordable and can replace traditional temperature measurement which often couldn't tell the real dew point. Η215 outputs the measurement value through the loop powered 4-20 mA signal.
Features
• Affordable dew point sensors for mid-range applications such as refrigerant dryer monitoring
• Long term stability
• IP65 casing provides robust protection in rough industrial environment
• Very fast response time ensures safe and reliable indication whenever dew points are out of valid ranges
• Can be installed directly into dryers through G 1/2" thread
• High accuracy of ±2 ºC dew point
Sigma 220 Dew point sensor
Dew point sensor, -100 ... 0 ºC, G 1/2” thread, 16 bar, 1 x 4...20 mA.
The Sigma 220 Dew point sensor provides reliable and long term stable dew point monitoring in industrial applications. Η220 is using a new sensor technology which has superior signals at very low moisture levels thus providing reliable measurements down to –100 ºC.
A stainless steel mesh filter with pore sizes below 1 um protects the sensor from particles. It’s designed for applications where very low moisture levels needs to be detected.
The measured dew point is output through a 4-20 mA signal (3-wire or loop powered). Sensor parameters such as analogue output scaling, physical units, can be easily changed by using a service kit.
Stated accuracy under following conditions:
- Ambient temperature 23 +/- 3 ºC
- Process temperature 23 +/- 3 ºC
- Ambient humidity <95%, no condensate
- Airflow > 1 l/min at sensor tip
Features
- Small size makes it ideal for dryer installations
- Measures dew points down to –100 ºC
- New sensor technology
- Version with integrated pressure measurement
- Various output versions available: 1 x 4...20 mA, 2 x 4...20 mA, RS-485 (Modbus), 4...20 mA loop powered
- Very fast response time ensures safe and reliable indication whenever dew points are out of valid ranges
- IP65 casing provides robust protection in rough industrial environment
- Can be installed directly into dryers through G 1/2” thread
- High accuracy of 2 ºC dew point
- M12 connector
The Η220 is powered by a current loop, and three wires.
Sigma 305 Dew Point Monitor for Desiccant and Fridge Dryers
(-50… +20 °C Td / -20 … +50 °C Td)
100 ... 240 VAC version
Refrigerated-Dryers are among the most used dryers in compressed air. Many of these dryers are not performing as intended, too often a lack of maintenance and quality issues result in very high dew points and water in the pipes. In other words: Energy is used for nothing. The dew point indicator at the dryer is not really measuring the dew point but the evaporation temperature. Only the "real"dew point measurement of the outlet air provides reliable results.
The All-In-One solution allows a convenient and price attractive dew point monitoring of refrigerated dryers. Alarm indications offer a timely maintenance avoiding costly system shut downs.
Under normal operation conditions Η305 can be used for 2 years without any re-calibration.
Stated accuracy under following conditions:
• Ambient temperature 23 +/- 3 ºC
• Process temperature 23 +/- 3 ºC
• Ambient humidity <95%, no condensate
• Airflow > 1 l/min at sensor tip
Technical information
Measuring range: | -20...+50°C |
Accuracy: | 1 ... 2 °C dew point |
Pressure range: | -0.1 ... 5.0 MPa |
Power supply: | 100 ... 240 AC / 10 VA |
Measured gas: | Non-corrosive gasses |
Ambient conditions: | -10 ... 40 °C |
Transport: | -30 ... +70 °C |
Responsetime t90: | < 30 sec (descending) < 10 sec (ascending) |
Output signal: | 4 ... 20 mA |
Gas connection | 6 mm hose quick connector |
Cable glands: | 2 cable glands for supply and signal cable |
Casing | Process connection: stainles steel Casing: AI alloy, ABS |
Classification: | IP65 |
Sensor protection: | Stainless steel sinter cap pore size < 30 um |
EMC: | According to IEC 61326-1 |
Α red light and buzzer alarm, wall mountable version is also available.
The unit is using the relay outputs of Sigma 305 to trigger the alarm